Mobile Gasoline Turbo Smoke Exhaust Fan Positive Pressure Fire Smoke Exhaust Fan

Product Details
Customization: Available
Material: Aluminum
Usage: for Manufacture
Still deciding? Get samples of US$ 1980/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 30 days
Low MOQ
The MOQ for the supplier's products is 1
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (26)
  • Mobile Gasoline Turbo Smoke Exhaust Fan Positive Pressure Fire Smoke Exhaust Fan
  • Mobile Gasoline Turbo Smoke Exhaust Fan Positive Pressure Fire Smoke Exhaust Fan
  • Mobile Gasoline Turbo Smoke Exhaust Fan Positive Pressure Fire Smoke Exhaust Fan
  • Mobile Gasoline Turbo Smoke Exhaust Fan Positive Pressure Fire Smoke Exhaust Fan
  • Mobile Gasoline Turbo Smoke Exhaust Fan Positive Pressure Fire Smoke Exhaust Fan
  • Mobile Gasoline Turbo Smoke Exhaust Fan Positive Pressure Fire Smoke Exhaust Fan
Find Similar Products

Basic Info.

Model NO.
GF
Flow Direction
Axial Flow
Pressure
Positive Pressure
Certification
RoHS, CE, CCC
Run Time
58minute
Power
Honda 4-5HP
Flow
17099-46750m³/H
Net Weight
30-21kg
Size
16′′-24′′
Blade Material
Cast Iron
Transport Package
Wooden Case
Specification
16′′; 21′′; 24′′
Trademark
SNTOOM
Origin
Zhejiang, China
Production Capacity
5000 Piece/Pieces Per Month

Product Description

Specification
Product Name
positive pressure gasoline turbine smoke extractor
Model
GF164SE-16"/40cm
GF210-21"/54cm
GF240-24"/60cm
power
Honda5.5hp
Honda5.5hp
Honda5.5hp
Wind blade
400mm*7 blades
540mm*7 blades
600mm*7 blades
Running time
58 min
58 min
58 min
Weight(kg)
29
40
52
Exhaust smoke volume(m/hr)
19810
30039
46750
Volume(h*w*d)
533*508*432
641*616*495
737*711*531
Main features:
Large capacity turbine ventilation fan, suitable for warehouses, commercial buildings, and large buildings.
HONDA5.5hp engine with a 2:1 gearbox reduces noise and vibration, increasing safety.
Aluminum cast turbine blades with high dynamic balance accuracy, 1800 revolutions per minute, can greatly reduce the probability of machine stress and damage.
Quick and convenient foot positioning settings.
Scalable handle for convenient push-pull operation.
A sturdy 32mm powder coated steel frame.
Inflatable tires suitable for rugged terrain.
Optional large diameter exhaust pipe.


I Scope of use
    Widely applicable to areas containing flammable gases, vapors, dust, etc. caused by chemicals, processing and manufacturing, and welding, it is safe and explosion-proof, and can discharge flammable and explosive gases from hazardous areas.

II Characteristics
    The power of turbine exhaust fans is a weapon for firefighters to fight and control building fires. The unique blade design can quickly generate a strong airflow, creating conditions for positive pressure air supply. The rapid and effective smoke exhaust and air supply technology is a guarantee for the safety of firefighters and those trapped in fires. The "Zhejiang Wind" series of fan smoke exhaust fans send outdoor air into the building, increasing the air pressure inside the building and forming a pressure difference with the external air. Under such a pressure difference, positive indoor air will quickly flow to the outside, achieving the purpose of smoke exhaust and air supply.

III Operating instructions
1. When starting the fan for the first time, if there is any damage during transportation, especially the blades, protective cover or casing, do not start the fan. If you have any questions about any damage, please contact the dealer immediately.
2. Use appropriately sized wires to withstand current loads (refer to label data).
3. Before connecting to the power cord, ensure that the switch is in the "off" state.
4. Place the fan upright and steadily before starting.
5. If there is any machine noise, vibration or other abnormal phenomena, the fan should be immediately turned off (except for the blades, any noise or vibration of any component of the fan is considered an abnormal phenomenon).
6. It is prohibited to move the fan during operation.
7. When using the fan, please pay attention to the airflow direction indicator arrow on the casing.
8. When using air ducts, it is important to ensure that the duct sleeve is securely fixed to the duct adapter.
9. Before storage, please cool the fan.
10. Be careful when placing and storing to avoid external damage

Mobile Gasoline Turbo Smoke Exhaust Fan Positive Pressure Fire Smoke Exhaust FanMobile Gasoline Turbo Smoke Exhaust Fan Positive Pressure Fire Smoke Exhaust FanMobile Gasoline Turbo Smoke Exhaust Fan Positive Pressure Fire Smoke Exhaust FanMobile Gasoline Turbo Smoke Exhaust Fan Positive Pressure Fire Smoke Exhaust FanMobile Gasoline Turbo Smoke Exhaust Fan Positive Pressure Fire Smoke Exhaust FanMobile Gasoline Turbo Smoke Exhaust Fan Positive Pressure Fire Smoke Exhaust Fan

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier